{"product_id":"dell-poweredge-r740xd-24-bay-8x-nvme-chassis","title":"Dell PowerEdge R740xd 24-Bay 2.5\" 8x NVMe [14th Gen]","description":"\u003cp\u003e\u003cstrong\u003eHybrid backplane: 16 SAS\/SATA + 8 NVMe.\u003c\/strong\u003e This page is the R740xd 24-Bay 2.5\" with the 8-bay NVMe flex-zone backplane: sixteen hot-swap SAS\/SATA bays on the SAS expander plus eight PCIe-attached U.2 NVMe bays. The configurator caps NVMe drives at 8 on this page. Need twelve NVMe bays? Use the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-12x-nvme-chassis\"\u003e24-Bay 2.5\" 12x NVMe\u003c\/a\u003e companion. Need all-NVMe? Use the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-nvme-build-your-own\"\u003e24-Bay 2.5\" 24x NVMe\u003c\/a\u003e page. Only four NVMe bays needed? The \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-2-5-chassis\"\u003e24-Bay 2.5\" 4x NVMe\u003c\/a\u003e page is the lower-cost option. The platform notes below are shared across the 24-Bay 2.5\" family.\u003c\/p\u003e\u003cp\u003eThe R740xd 24-Bay 2.5\" is the SFF density companion in the R740xd family and the only R740xd variant that meaningfully supports GPU. Twenty-four hot-swap 2.5\" front bays via a SAS expander backplane, optional mid-bay or rear flex bay expansion, flex-zoning to bring 8 to 12 NVMe drives into the SAS\/SATA front bays as a hybrid mix, and the GPU envelope the LFF variants do not have. The Intel Purley dual-socket compute platform is identical to the 12-Bay 3.5\" reference page; what's different is the front backplane (SFF + SAS expander instead of LFF direct-attach) and the riser layout that opens up GPU support.\u003c\/p\u003e\u003cp\u003eFor the IT director sizing a vSAN OSA all-flash node, a Ceph all-flash OSD node, a database server with a local SSD tier, a VDI host with vGPU, or any high-IOPS SDS deployment where SSDs are the right drive class, this is the R740xd configuration we reach for. For bulk LFF capacity at lowest cost-per-TB the \u003ca href=\"\/products\/dell-poweredge-r740xd-12-bay-3-5-chassis\"\u003e12-Bay 3.5\" reference page\u003c\/a\u003e is the cleaner spec; for all-NVMe across all front bays the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-nvme-build-your-own\"\u003e24-Bay 2.5\" 24x NVMe\u003c\/a\u003e companion is the dedicated NVMe specialist. The variant decision usually comes down to drive class and GPU requirements; the When 24-Bay 2.5\" Is the Right Choice section below covers it.\u003c\/p\u003e\u003cp\u003eTo configure a build, call \u003cstrong\u003e1-800-778-1545\u003c\/strong\u003e for our account team. Every R740xd we ship runs through a \u003cstrong\u003e12+ hour\u003c\/strong\u003e burn-in across every memory channel, every PCIe slot, every drive bay including mid-bay positions if equipped, and every GPU slot under load for GPU-equipped builds. Every unit ships with a \u003cstrong\u003e180-day\u003c\/strong\u003e standard warranty and 1-Year, 2-Year, and 3-Year Premium options at quote time. Volume pricing applies at \u003cstrong\u003e5 units\u003c\/strong\u003e and above; tell us your workload and quantity and we will steer you to the right R740xd variant or to an adjacent platform if the data supports it.\u003c\/p\u003e\u003ch2\u003eWhen 24-Bay 2.5\" Is the Right Choice\u003c\/h2\u003e\u003cp\u003eThe 24-Bay 2.5\" earns its place in the R740xd family on three things: SFF density (24 SSDs front, expandable to 28 with rear flex bay), GPU support (the only R740xd variant that has it), and drive-class flexibility (SAS + SATA + flex-zone NVMe in one chassis). We pick it for high-IOPS workloads, for SDS at scale on flash, and for any 2U deployment where compute density matters as much as storage density.\u003c\/p\u003e\u003cp\u003ePick the 24-Bay 2.5\" when:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe workload is random-IOPS sensitive and the 12-Bay 3.5\" with NL-SAS will not deliver the IOPS profile\u003c\/li\u003e\n\u003cli\u003eYou need GPU support on an R740xd-class chassis (1-3 double-width 300W GPUs, or 1-6 single-width 150W GPUs)\u003c\/li\u003e\n\u003cli\u003eYou want a hybrid SAS\/SATA + NVMe mix via flex-zoning (typically 16 SAS\/SATA + 8 NVMe, or 12 + 12)\u003c\/li\u003e\n\u003cli\u003eYour single-chassis SFF capacity target is 100 to 180 TB raw (24 x 7.68 TB SAS SSD = 184 TB; 15.36 TB SSD ladders push higher)\u003c\/li\u003e\n\u003cli\u003eYou are building vSAN OSA all-flash, Ceph all-flash OSD, large database servers with local SSD tier, or VDI with high user density\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePick a different R740xd variant when:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBulk capacity at lowest cost-per-TB matters more than IOPS (the \u003ca href=\"\/products\/dell-poweredge-r740xd-12-bay-3-5-chassis\"\u003e12-Bay 3.5\"\u003c\/a\u003e with NL-SAS is the right call)\u003c\/li\u003e\n\u003cli\u003eYou need all-NVMe across all 24 bays with native PCIe-attached backplane (the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-nvme-build-your-own\"\u003e24-Bay 2.5\" 24x NVMe\u003c\/a\u003e companion is the dedicated NVMe specialist)\u003c\/li\u003e\n\u003cli\u003eYou need 28 SFF in a single chassis with rear bays (the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-4-bay-rfb-build-your-own\"\u003e+ 4-Bay RFB\u003c\/a\u003e companion is the maximum-SFF-density variant)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eStorage - 24x 2.5\" SFF Front Bays\u003c\/h2\u003e\u003cp\u003eTwenty-four hot-swap 2.5\" front bays. On this page sixteen run SAS\/SATA on the SAS expander backplane and eight are PCIe-attached NVMe. The SAS expander routes the SAS\/SATA bays through a single PERC connection, which is more efficient than direct-attach but adds the expander firmware as a troubleshooting layer if you hit obscure bay-enumeration issues; we firmware-check the expander as part of burn-in.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFlex-zoning for NVMe:\u003c\/strong\u003e The 24-bay SAS\/SATA backplane supports flex-zoning where some bays are routed off the SAS expander and onto PCIe-attached NVMe controller cards. Common configurations:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 SAS\/SATA + 8 NVMe:\u003c\/strong\u003e This page. Typical for SQL Server with NVMe hot tier and SAS SSD warm tier, or for vSAN OSA with NVMe cache and SAS SSD capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 SAS\/SATA + 12 NVMe:\u003c\/strong\u003e Maximum NVMe in flex-zoning on this chassis, sold on the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-12x-nvme-chassis\"\u003e12x NVMe\u003c\/a\u003e page. If you need more than 12 NVMe drives, route to the dedicated 24x NVMe companion.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFlex-zoning NVMe drives are not on the PERC; they are direct PCIe-attached and present individually to the OS. Hardware NVMe RAID is not available on 14th gen (the H740P does not RAID NVMe). For NVMe RAID, the options are Intel VROC (chipset-level, BIOS-enabled, has its own configuration constraints), ZFS \/ mdadm \/ Storage Spaces software RAID, or an SDS stack like vSAN that handles redundancy at the layer above the drives. We are direct about this at quote time: if hardware NVMe RAID is the requirement, 14th gen is not the platform and 16th gen R760xd2 with H965i tri-mode is the upgrade path.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMid-bay expansion:\u003c\/strong\u003e Optional 4x 2.5\" mid-drive tray adds four additional SFF bays inside the chassis, bringing front+mid to 28 SFF. The 2.5\" mid-bay supports NVMe in the mid position. Critical constraint: \u003cstrong\u003emid-bay and full GPU support are mutually exclusive\u003c\/strong\u003e because the mid-bay assembly consumes the GPU riser slot. Pick GPU OR mid-bay, not both.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRear flex bay (RFB) option:\u003c\/strong\u003e The 24-Bay 2.5\" can be configured with a 4x 2.5\" rear flex bay, bringing front+rear to 28 SFF total. That configuration is sold as a separate SKU; route to the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-4-bay-rfb-build-your-own\"\u003e24-Bay 2.5\" + 4-Bay RFB\u003c\/a\u003e companion page if rear bays are in your spec.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDrive options we quote:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAS SSD Read-Intensive:\u003c\/strong\u003e 1.92 TB, 3.84 TB, 7.68 TB. Volume sweet spot for SDS deployments. 15.36 TB available at premium pricing; volume capacity buyers typically land on the 7.68 TB tier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSAS SSD Mixed-Use:\u003c\/strong\u003e 1.92 TB, 3.84 TB. For write-intensive workloads (cache tier, OLTP databases, vSAN cache disks).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSATA SSD Mixed-Use:\u003c\/strong\u003e 1.92 TB, 3.84 TB. Cost-effective for general VM storage where SAS premium is not justified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10K SAS HDD:\u003c\/strong\u003e 1.2 TB, 2.4 TB. For mixed deployments with moderate IOPS needs at lower cost per TB than SSD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eU.2 NVMe (flex-zoning):\u003c\/strong\u003e 1.92 TB, 3.84 TB, 7.68 TB. Up to 8 slots on this page. RAID requires software (Intel VROC, ZFS, mdadm, or SDS layer).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRAID guidance for SFF SSD arrays:\u003c\/strong\u003e SSDs handle RAID 5 substantially better than spinning disk because the rebuild window is short (a 3.84 TB SSD rebuilds in 2 to 4 hours under load, versus 24 to 36 hours for a 16 TB NL-SAS) and the unrecoverable-read-error rate is lower. RAID 5 is acceptable for SSD arrays up to 6 drives. Above 6 drives we recommend RAID 6 for the second-failure margin during rebuild. RAID 10 is the right call for write-heavy workloads where the parity-write penalty is unacceptable. For SDS deployments (vSAN OSA, Ceph), use HBA330 in pass-through mode and let the SDS layer handle redundancy at its own level.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBoot:\u003c\/strong\u003e BOSS-S1 (Boot Optimized Storage Solution, dual mirrored M.2 SATA SSDs on a dedicated PCIe card, hardware RAID 1, cold-swap). Standard 14th gen boot device. We add it to every R740xd BOM by default; reserve all 24 front bays for the workload.\u003c\/p\u003e\u003ch2\u003eStorage Controllers\u003c\/h2\u003e\u003cp\u003eThe full 14th gen PERC family is available on the R740xd 24-Bay 2.5\" via the Mini-PERC slot. Controller selection is workload-driven: SDS deployments want HBA pass-through, transactional workloads want H740P, mixed and read-heavy workloads can sit at H730P. The controller manages the SAS\/SATA bays only; the NVMe bays are PCIe-attached.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePERC H740P (8 GB NV cache, battery-backed):\u003c\/strong\u003e Production storage default for SAS\/SATA workloads on this chassis. The 8 GB non-volatile cache and battery backing survive a power event without UPS dependency. For database servers, mixed I\/O workloads, or any SAS SSD array where the controller cache is the performance differentiator, H740P is the right call. Note that H740P does not RAID NVMe on 14th gen; flex-zone NVMe drives must be on software RAID or pass-through.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePERC H730P (2 GB cache, battery-backed):\u003c\/strong\u003e Solid general-purpose choice for mixed or read-heavy SAS\/SATA workloads where the 8 GB cache of the H740P is over-spec. Lower price point, same drop-in form factor. For general-purpose virtualization or file-server duty on SSD, H730P is often acceptable.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePERC H730 (1 GB cache, battery-backed):\u003c\/strong\u003e 13th-gen carryover via Mini-PERC slot compatibility. Viable on the R740xd 24-Bay 2.5\" but generally a downgrade vs the H730P or H740P on Cascade Lake workloads. Quote when budget is the hard constraint and write performance on SAS\/SATA is not load-bearing; quote H730P or H740P otherwise. Not a primary recommendation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePERC H330 (no cache):\u003c\/strong\u003e Entry-tier hardware RAID. Not appropriate for production SFF density deployments on this chassis. Listed for completeness.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHBA330 (pass-through HBA):\u003c\/strong\u003e Required for software-defined storage stacks (vSAN OSA, Storage Spaces Direct, Ceph, ZFS). The HBA presents disks directly to the OS or hypervisor without any RAID abstraction. HBA330 is the correct controller for those deployments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePERC H840 (external):\u003c\/strong\u003e For external SAS enclosure connectivity when scale-out beyond the internal bays is needed in a single chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eS140 (software RAID via chipset):\u003c\/strong\u003e Dev\/test and light workloads only. Not a production recommendation.\u003c\/p\u003e\u003ch2\u003eProcessors\u003c\/h2\u003e\u003cp\u003eThe R740xd 24-Bay 2.5\" supports 1st Generation Intel Xeon Scalable (Skylake-SP, 2017) and 2nd Generation Intel Xeon Scalable (Cascade Lake-SP, 2019) in the same LGA 3647 socket. Drop-in compatible, no BIOS forklift if firmware is current. Same V1 \/ V2 socket compatibility story as the rest of the 14th gen family.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCPU selection is workload-dependent on this chassis more than on the LFF variants\u003c\/strong\u003e because the workloads run on the 24-Bay 2.5\" tend to be compute-active rather than storage-throughput-bound. Our recommendations:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold 6230 (20 cores, 2.1 GHz, 125W TDP):\u003c\/strong\u003e Sweet spot for general SDS and mid-density virtualization. Forty cores total in a dual-socket build covers most vSAN and Ceph deployments with headroom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold 6248 (20 cores, 2.5 GHz, 150W TDP):\u003c\/strong\u003e When the chassis hosts a database server with active OLTP or a high-VM-density VDI cluster. Higher clock speed than the 6230 for latency-sensitive workloads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGold 6248R (24 cores, 3.0 GHz, 205W TDP):\u003c\/strong\u003e The high-clock, high-core option for transactional databases and per-core-licensed workloads (SQL Server Enterprise, Oracle). Requires the high-performance heatsink, see below.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlatinum 8280 (28 cores, 2.7 GHz, 205W TDP):\u003c\/strong\u003e When core count drives the licensing or capacity planning. Most R740xd 24-Bay 2.5\" workloads do not need Platinum-class; we quote it on specific request.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eHeatsink mismatch above 150W is the trap.\u003c\/strong\u003e Any processor above 150W TDP requires the high-performance heatsink. The standard heatsink will thermally throttle under sustained load. Confirm the heatsink at quote time against the CPU TDP.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSingle-socket disables half the platform.\u003c\/strong\u003e A single-socket R740xd 24-Bay 2.5\" leaves the second CPU's 12 DIMM slots unreachable, half the PCIe lanes unavailable (which is particularly costly on this chassis given the flex-zone NVMe and GPU consumption of PCIe lanes), and the second NDC slot inactive. We will steer customers away from single-socket builds here in almost every case.\u003c\/p\u003e\u003ch2\u003eMemory\u003c\/h2\u003e\u003cp\u003e24 DDR4 DIMM slots: 12 per CPU, 6 channels per CPU, 2 DIMMs per channel. Supports RDIMM up to 128 GB per DIMM, LRDIMM up to 256 GB per DIMM. Maximum capacity 3 TB with 128 GB RDIMMs at 2 DPC, 6 TB with 256 GB LRDIMMs, up to 7.68 TB combined with Intel Optane PMem 100-series on Cascade Lake L-series CPUs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMemory speed by population and generation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSkylake (V1):\u003c\/strong\u003e DDR4-2666 at 1 DPC, DDR4-2666 at 2 DPC (no penalty for full population)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCascade Lake (V2) Gold 6200 \/ 5222 SKUs:\u003c\/strong\u003e DDR4-2933 at 1 DPC, drops to DDR4-2666 at 2 DPC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCascade Lake (V2) other SKUs:\u003c\/strong\u003e DDR4-2666 at any population\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNVMe bifurcation BIOS setting:\u003c\/strong\u003e Flex-zone NVMe and PCIe-attached NVMe carriers require bifurcation enabled in BIOS before the drives will enumerate. Default BIOS does not enable bifurcation. We set this at burn-in for any R740xd shipped with flex-zone NVMe; if you are commissioning a unit from another source, check the BIOS first.\u003c\/p\u003e\u003ch2\u003eNetworking and PCIe Expansion\u003c\/h2\u003e\u003cp\u003eThe R740xd uses Dell's Network Daughter Card (NDC) mezzanine standard. The NDC slot is dedicated and does not consume a PCIe slot. NDC options: 4x 1 GbE (management only), 2x 10 GbE + 2x 1 GbE, 4x 10 GbE (Intel X710 or Broadcom 57414), and 2x 25 GbE (Mellanox ConnectX-4 Lx), our standard recommendation for SDS and NVMe-tiered workloads on this chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePCIe expansion:\u003c\/strong\u003e Up to 8 PCIe Gen3 slots in the base configuration. On this page the NVMe flex-zone controller cards consume part of that budget; GPUs, 100 GbE adapters, and additional HBAs compete for the rest. \u003cstrong\u003eNVMe flex-zone configurations limit GPU count to 2 maximum.\u003c\/strong\u003e We work through the slot map at quote time and tell you what does not fit.\u003c\/p\u003e\u003ch2\u003eManagement - iDRAC9 Generation\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eiDRAC9 Enterprise is the production spec.\u003c\/strong\u003e Full remote KVM with HTML5 console, virtual media for ISO mounting, group management via OpenManage Enterprise, Lifecycle Controller for firmware updates without OS involvement. We spec Enterprise on every R740xd 24-Bay 2.5\" BOM by default. Silicon Root of Trust, TPM 2.0, Secure Boot, signed firmware, and System Erase meet HIPAA, PCI DSS, CMMC, and federal civilian compliance requirements.\u003c\/p\u003e\u003ch2\u003ePower and Cooling\u003c\/h2\u003e\u003cp\u003eHot-swap redundant Dell Flex Slot PSUs: 495W, 750W (Platinum and Titanium), 1100W Platinum, 1600W Platinum, 2000W, 2400W. A balanced build (Gold 6230, 384 GB, 16 SSD + 8 NVMe, no GPU) sits comfortably on 2x 1100W Platinum. GPU-equipped builds step to 2000W or 2400W; coordinate PDU sizing with the rack design at quote time. Cooling is the standard 14th gen 2U fan kit, hot-swap, N+1 redundancy; GPU builds get the high-performance fan kit by default.\u003c\/p\u003e\u003ch2\u003eOur Assessment\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhere it excels:\u003c\/strong\u003e The hybrid page for buyers who want an NVMe hot tier without giving up SAS\/SATA capacity bays: SQL Server and Oracle with NVMe log and tempdb volumes over a SAS SSD data tier, vSAN OSA with NVMe cache disks and SAS SSD capacity disks, and virtualization hosts that keep latency-sensitive VMs on NVMe. It keeps the GPU envelope (2 GPUs with NVMe flex-zoned) and the full 14th gen PERC family for the SAS\/SATA bays.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere to look instead:\u003c\/strong\u003e Fewer NVMe bays needed, the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-2-5-chassis\"\u003e24-Bay 2.5\" 4x NVMe\u003c\/a\u003e page costs less. More NVMe needed, the \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-12x-nvme-chassis\"\u003e12x NVMe\u003c\/a\u003e page or the all-NVMe \u003ca href=\"\/products\/dell-poweredge-r740xd-24-bay-nvme-build-your-own\"\u003e24x NVMe\u003c\/a\u003e page. Bulk LFF capacity, the \u003ca href=\"\/products\/dell-poweredge-r740xd-12-bay-3-5-chassis\"\u003e12-Bay 3.5\"\u003c\/a\u003e. Hardware NVMe RAID, step to 16th gen R760xd2 with PERC H965i.\u003c\/p\u003e\u003ch2\u003eReady to Configure?\u003c\/h2\u003e\u003cp\u003eTell us your workload, target CPU class, memory capacity, drive configuration (SAS \/ SATA \/ NVMe mix, capacity per drive, RAID strategy), GPU requirements if any, network bandwidth, and quantity. Our account team will put together a tailored quote within 24 hours. Call \u003cstrong\u003e1-800-778-1545\u003c\/strong\u003e. Every R740xd ships with a \u003cstrong\u003e180-day\u003c\/strong\u003e standard warranty, runs through our \u003cstrong\u003e12+ hour\u003c\/strong\u003e burn-in with full SMART validation on every drive bay, and qualifies for volume pricing at \u003cstrong\u003e5 units\u003c\/strong\u003e and above. \u003ca href=\"\/pages\/quote-cart\"\u003eRequest a Quote\u003c\/a\u003e | \u003ca href=\"\/pages\/contact\"\u003eContact our account team\u003c\/a\u003e\u003c\/p\u003e","brand":"Dell","offers":[{"title":"Default Title","offer_id":67976102904007,"sku":"BP-0000003","price":384.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0748\/4493\/0247\/files\/dell-poweredge-r740xd-24-bay-nvme-server-904758.png?v=1765539751","url":"https:\/\/wholesaleservers.com\/products\/dell-poweredge-r740xd-24-bay-8x-nvme-chassis","provider":"Wholesale Servers","version":"1.0","type":"link"}